Fire Alarm System Planned/Reactive Service & Maintenance

Mains Interlinked, Conventional and Addressable Hard-wired & Wireless Fire Alarm Systems

If you'd prefer to order a hardcopy, please complete the following short form to order your Signs Catalogue:

Thank you! Your catalogue will be with you soon.
Oops! Something went wrong while submitting the form.
Download/order your copy of the 2020-21 Signs Catalogue today:
Please note this document will be downloaded via Dropbox. If you do not have a Dropbox account, please click on ‘No thanks, continue to view’ and document will download to your device.
Download your copy of ‘COVID-19 Safety Signage Catalogue July 2020'
Losing footfall due to COVID-19? Download our Retail Signage Catalogue

Fixfire® is BAFE accredited for the Design, Installation, Maintenance and Servicing of Fire Alarm Systems.

All works are carried out by our employed, uniformed and trained Fire Alarm engineers.
Following each visit, a Certificate of Inspection is issued.

On our first visit, if necessary, we will train staff to fulfil their own obligations, eg. weekly test of the fire alarm system and monthly test of emergency lighting. Any necessary test keys will also be supplied.

Planned engineer fire alarm maintenance/service is carried out in accordance with BS5839 Part 1 which specifies a minimum frequency of every 6-months. Additional fire alarm visits may be deemed necessary subject to your Fire Risk Assessment, typically this may apply to higher risk premises such as Hotels, Hospitals and Care Premises.

Fixfire® provides 24/7 planned and reactive fire alarm maintenance/service for most makes and type of fire alarm systems irrespective of the original installing company.

Where Fixfire® takes over fire alarm service/maintenance were commend that a ‘Special Inspection’ is conducted as laid out in BS5839 Part1.

On the ‘Special Inspection’, the fire alarm system is thoroughly examined and bench marked against relevant sections of the current British Standard.
The following examples would be regarded as non-compliances:

  • Inadequate number of Manual Call Points.
  • Inadequate provision of fire detection for the designed Category of system.
  • Inadequate Fire Alarm audibility.
  • Standby power supplies that fail to conform.
  • Cabling with fire resistance that fails to conform
  • Monitoring of circuits that fail to conform.
  • Standards of electrical safety that do not conform. 
  • Exposure to, or experience of, false fire alarms.
  • Changes in the use, layout and construction oft he protected premises that may impact on the effectiveness of the system.
  • The absence of a zone plan or other suitable diagrammatic representation of the premises.

Whilst the ‘Special Inspection’ is not a mandatory requirement, we strongly recommend the visit for your own peace of mind in order to ensure that there are no fundamental issues that could have a detrimental effect on the performance of the fire alarm system in a critical situation.

The Fixfire® Fire Log Book fits perfectly with our maintenance system and provides entries for engineer and user testing with dedicated sections for the storage of maintenance certificates.

Compliance with current Fire Safety Law (Regulatory Reform (Fire Safety) Order 2005) is a tall order and keeping tabs on due dates across multiple assessments, checks and inspections without missing something is a real challenge.

The Fire Safety Compliance System from Fixfire® provides you with the tools, support and expertise to drive your compliance with confidence.

Please call our Compliance Team today to discuss your Fire Alarm Service and Maintenance requirements.

Freephone 08000891999

KeyCall® is a revolutionary patent-pending Key Operated Fire Alarm Activation Device which has been developed specifically for ‘approved’ applications where standard fire alarm call points would be vulnerable to abuse. Developed by Fixfire® in response to growing demand from the Mental Health Care sector, KeyCall® is a revolutionary one-piece analogue addressable key operated manual call point.

Compatible with a wide range of Conventional and Addressable Fire Alarm Systems.

KeyCall® accepts a Euro-Profile style cylinder
Typically suited/keyed-alike cylinders are fitted so that authorised persons can activate KeyCall® using their standard door key.

Key ‘Click-latch’ mechanism ensures key ‘latches’ in correct position to activate Fire Alarm System.

Anti-ligature low-profile flush-mounting design.

Neat minimalistic one piece construction incorporating Fire Alarm interface module.

Red fire indicator illuminates when KeyCall® is activated.

Compatible with a wide range of Conventional and Addressable Fire Alarm Systems

Applications include:

  • Prisons
  • Mental Healthcare
  • Special Educational Needs (SEN) School
Read More...
 

Fire Alarm Service and Maintenance

Fire Alarm Service and Maintenance

Fire Alarm Service and Maintenance

British Standard Design requirements...
  • Install AFD to voids greater than 800mm
  • Treat downward projections exceeding 10% of the void depth as wall
BS5839-Part 1:2013 states:

22.2d) If the system Category is such that automatic fire detection should be provided in any area that contains a horizontal void of 800 mm or more in height, automatic fire detection should also be provided in the void.

22.3j) Ceiling obstructions, such as structural beams, deeper than 10% of the overall ceiling height should be treated as walls [see Figure 10a)]. NOTE 10 Within horizontal voids, beams or obstructions that are deeper than 10% of the overall depth of the void regardless of whether the void is above the ceiling or below the floor, ought to be treated as walls that subdivide the void.

Download Standard Range Brochure

Please complete the following form to access your download.

Thank you! Your submission has been received!
DOWNLOAD
Oops! Something went wrong while submitting the form.
VoidAlert Remote Indicator
Related Downloads
Related Downloads
The Fixfire Fire Safety Compliance System

Click a sector to find out more

Fixfire® is BAFE accredited for the Design, Installation, Maintenance and Servicing of Fire Alarm Systems.

All works are carried out by our employed, uniformed and trained Fire Alarm engineers.
Following each visit, a Certificate of Inspection is issued.

On our first visit, if necessary, we will train staff to fulfil their own obligations, eg. weekly test of the fire alarm system and monthly test of emergency lighting. Any necessary test keys will also be supplied.

Planned engineer fire alarm maintenance/service is carried out in accordance with BS5839 Part 1 which specifies a minimum frequency of every 6-months. Additional fire alarm visits may be deemed necessary subject to your Fire Risk Assessment, typically this may apply to higher risk premises such as Hotels, Hospitals and Care Premises.

Fixfire® provides 24/7 planned and reactive fire alarm maintenance/service for most makes and type of fire alarm systems irrespective of the original installing company.

Where Fixfire® takes over fire alarm service/maintenance were commend that a ‘Special Inspection’ is conducted as laid out in BS5839 Part1.

On the ‘Special Inspection’, the fire alarm system is thoroughly examined and bench marked against relevant sections of the current British Standard.
The following examples would be regarded as non-compliances:

  • Inadequate number of Manual Call Points.
  • Inadequate provision of fire detection for the designed Category of system.
  • Inadequate Fire Alarm audibility.
  • Standby power supplies that fail to conform.
  • Cabling with fire resistance that fails to conform
  • Monitoring of circuits that fail to conform.
  • Standards of electrical safety that do not conform. 
  • Exposure to, or experience of, false fire alarms.
  • Changes in the use, layout and construction oft he protected premises that may impact on the effectiveness of the system.
  • The absence of a zone plan or other suitable diagrammatic representation of the premises.

Whilst the ‘Special Inspection’ is not a mandatory requirement, we strongly recommend the visit for your own peace of mind in order to ensure that there are no fundamental issues that could have a detrimental effect on the performance of the fire alarm system in a critical situation.

The Fixfire® Fire Log Book fits perfectly with our maintenance system and provides entries for engineer and user testing with dedicated sections for the storage of maintenance certificates.

Compliance with current Fire Safety Law (Regulatory Reform (Fire Safety) Order 2005) is a tall order and keeping tabs on due dates across multiple assessments, checks and inspections without missing something is a real challenge.

The Fire Safety Compliance System from Fixfire® provides you with the tools, support and expertise to drive your compliance with confidence.

Please call our Compliance Team today to discuss your Fire Alarm Service and Maintenance requirements.

Freephone 08000891999

Read More...
Patient Call System Accessories
Download Nurse Call System Accessories Brochure

Please complete the following form to access your download.

Thank you! Your submission has been received!
DOWNLOAD
Oops! Something went wrong while submitting the form.
Standard Call Leads
Intercall

Compatible with all Intercall® systems manufactured since 2005. (Includes all Intercall® 700 systems. For earlier versions and other systems which use a mono-jack connector see ‘Other Systems’.

NALL100 (2m)
NALL101 (4m)
NALL102 (6m)

Styled 2m ,4m and 6m pear push wander lead with reassurance light.

NALL200

Styled 2m call and bed light control handset. For Intercall® systems with overbed light switching facility

Other Systems

CareAlert offers an extensive range of call leads and accessories to suit the majority of Call Systems.

Other Systems

Please call Customer Support with your specific requirements and we will be glad to help.

Quantec & Nursecall 800

Compatible with all Quantec and Nursecall 800 systems.

NALC100 (1.8m)
NALC101 (4.2m)

1.8m or 4.2 tail call lead.

Disc-Alert

Disc-Alert is used by patients with sufficient motor skills to either press or lean on the pad to activate a call. It has a large circular shape and soft vinyl pad design with gripping feet to help keep it in position.

Bulb-Alert

Bulb-Alert is used by patients with sufficient motor skills to either press or lean on the bulb to activate a call. It has an oval shaped, soft final bulb design that prevents it from rolling off the patient’s bed.

NAAD200

Bulb-Alert with 6ft lead, compatible with Intercall® Systems.

NAAD100

Disc-Alert with 6ft lead or head-Alert with 8ft length compatible with Intercall® Systems.

NAAD300

Head-Alert with 8ft length lead compatible with Intercall® Systems.

Head-Alert

Head-Alert is used by patients with sufficient motor skills to either press or lean on the pad with their head to activate a call. Head-Alert features a large soft elliptical
air activated touch surface.

Breath-Alert

Breath-Alert provides patients with no motor skills a means to communicate by simply breathing into a sensitive pressure-operated switch. With a clamp providing easy attachment to a fixed support such as a bed or wheelchair, Breathcall incorporates a vinyl-covered flexible gooseneck which may be positioned to suit patient requirements. Two models are available, standard which has 3ft gooseneck and universal screw clamp for secure mounting and lightweight which has a 2ft gooseneck and ‘bulldog-clip’ type spring clamp. Both models come with a pack of disposable filters which should be changed regularly. Spare filters are available in packs of 12.

NAAD400

Standard Breath-Alert Unit complete with 9ft call lead, compatible with Intercall® Systems.

NAAD401

Lightweight Breath-Alert Unit complete with 9ft call lead, compatible with Intercall® Systems.

NAAD402

Breath-Alert Accessory Pack complete with 12 filter assemblies with soft straws and porous plastic filters.

Special Call Leads
Contact us today to see how Fixfire® can help your organisation
Contact us today
08000 891 999
GET IN TOUCH